Category: DC to DC
Overall Size: 11” X 5” X 3.75”
General Specifications:
Input
Low Line …………………………………………………………………… 22.0+0.0/ -0.20 VDC
Nominal …………………………………………………………….…………..… 28.0 +/-1 VDC
High Line ……………………………………………………………..……… 32.0+0.2/-0.0 VDC
Nominal Vout |
Full Load |
Min Input Load |
Max Ripple, 5MHz Bandwidth |
Max Ripple, 100MHz Bandwidth |
Maximum Allowed Voltage |
5.10 ± .15 VDC |
7.5 ADC |
1.0 ADC |
100 mV, p-p |
500mV, p-p |
6.25V |
+15.2 +0.1/-0.2VDC |
.450 ADC |
0 ADC |
150 mV, p-p |
200mV, p-p |
18.75V |
+15.2 +0.1/-0.2VDC |
.450 ADC |
0 ADC |
150 mV, p-p |
200mV, p-p |
18.75V |
+15.2 +0.1/-0.2VDC |
.450 ADC |
0 ADC |
150 mV, p-p |
200mV, p-p |
18.75V |
+15.2 +0.1/-0.2VDC |
.450 ADC |
0 ADC |
150 mV, p-p |
200mV, p-p |
18.75V |
Design Application: Helicopter Threat Warning System
Combines with our 9086-02
Employment opportunities, if you’re looking for employment please send your resume and a note to Request A Quote
@2021 Ensign